Paving the floor, the consumer acceptance often do not know where to start from several aspects, the results until the occurrence of quality problems occur when the dispute was discovered, there are many problems can be found early detection and early solution, so the correct acceptance of the quality of wood floor pavement is Consumers safeguard their own rights and interests.
Kanghui laminate flooring
The surface of the paved wooden floor was planed and polished, with no scars, russia and burrs. The pattern was clear, the color of the clean oil surface was the same, the laying direction was correct, the surface seams were tight, the joints were staggered, and the surface was clean. The skirting boards have tight joints, smooth surfaces, and a uniform height and wall thickness. With a 2-meter ruler check, the floor lay flatness error is less than 1 mm, the gap width is less than 0.3 mm, and the flatness error of laying on the baseboard mouth is less than 3 mm, and the patch straightness error is less than 2 mm.
The common quality problems and treatment methods of wood floor construction laying
The common quality problems in the laying of wooden floors are the sound of empty drums when walking, the unevenness of laying surfaces, lax seams, and local warping drums.
(1) The sound of empty drums: The reason is that the laying of the wooden floor is not fixed. The main reason is that the number of the board and the keel, the board and the floor nails are not enough or the nails are not firm. Sometimes the shrinkage or glue is caused by the change of the moisture content of the board. Liquid failed. In addition to the strict acceptance of control methods, moisture content, adhesive and other quality, can only be used after acceptance, outside the installation should not be too little nails, and should ensure that the nails, after each laying a wooden floor, with no foot after the foot test sound loaded A piece, if any sound should be reworked immediately.
(2) Uneven pavement surface: The main reason is that the laying of the grass roots is not flat or the wooden flooring strip deforms. During the construction of the paving, the horizontal ruler shall be used to check the level of the surface of the keel. If the paving is uneven, the paving shall be adjusted. Ventilation slots should be made on the keel. A 10 mm ventilation gap should be left on the edge of the wall. The insulation material must be dry to prevent arching after the floor is wet. The flatness of the wooden floor surface should be within 1 mm.
(3) Slotless lacing: In addition to the non-standard laying during construction, the large width and size of the plate and the poor quality of the machine are also important reasons. In addition to careful inspection of the floor quality during the construction, the installation should be Meikou. To nail nails in front of the board and use the module to mold the floor gaps and nail them.
(4) Partial warping drum: The main reason is that in addition to moisture deformation of the board, there are also small or seamless seams on the wool board, which is caused by the leakage of water in the floor and wet floors. In the construction period, 3 mm gap should be left when installing the wool board, and wooden keel carved ventilation slots. After the floor is covered, the paint on the floor paint should be complete. In daily use, water should be prevented from flowing into the lower part of the floor, and the surface water must be cleaned in time.