Schneider Korea Sanhe EOCR-FMZ2-WRCUW motor protector

Schneider Korea Sanhe EOCR-FMZ2-WRCUW motor protector built-in microprocessor unit real-time process / high-precision Schneider South Korea three and EOCR-FMZ2-WRCUW motor protector

China Hardware Business Network

Sanhe EOCR Co., Ltd. is Korea's largest manufacturer of motor protectors. The company was founded in 1981 by Dr. Jin Renxi (CEO of Schneider Electric Group Korea).

In 2001, in order to develop the company into a global, strategic enterprise, he joined the Schneider Electric Group of France.

EOCR's main products are electronic motor protection relays, electronic overcurrent relays, electronic undercurrent relays, electronic undervoltage relays, other protection and monitoring devices, and current transformers.




â—† Built-in microprocessor unit â—† Real-time process/high precision â—† With over-temperature inverse time protection without external CT current within 32A â—† Communication method: Modbus/RS-485
â—† Enhanced monitoring function: communication transmission distance up to 400 meters, 3-phase current display, trip cause display â—† Current amplitude display bar, trip cause display, applicable to single-phase and three-phase motors

◆ Comply with the relevant provisions of the “Regulations on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment” RoHS

â—† For split products, normal protection is provided even if PDM is not connected



EOCR-3MZ2/FMZ2 Protection Project
Protection project Setting range and conditions Action time
Overcurrent The load operating current (ln) exceeds the set overcurrent value (ls), ie ln≥ls
Setting range: 0.5~60A (Definite time limit - Def)
0.5~32A (inverse time limit - Inv, overheating inverse time limit - th)
Time limit: 0.2~30 seconds optional inverse time limit and overheating inverse time limit: 1~30 level
Undercurrent The load operating current (ln) is lower than the set overcurrent value (uc), ie ln ≤ uc
Undercurrent value setting cannot exceed or equal to overcurrent setting value
OFF, adjustable from 1 to 10 seconds
Stall This value is set to a multiple of the overcurrent setting value. It is suitable for the setting range during startup: 0.5~30A 2~8 times of the overcurrent setting value is more than 2~6 times of the 40A overcurrent setting value until 60A 2 to 4 times the current setting value 0.5 seconds after D-Time
Stall This value is set to a multiple of the overcurrent set value. It is suitable for the setting range during operation: 1.5~5 times of 0.5~50A overcurrent setting value up to 1.5~4 times of 60A overcurrent setting value. Adjustable from 0.2 to 5 seconds
Missing phase The maximum phase imbalance ratio of the three-phase current exceeds 85% (OFF/ON) OFF, adjustable from 0.5 to 5 seconds
Reverse phase The phase sequence of the three-phase current is not reciprocal (OFF/ON) OFF, within 0.15 seconds
Current imbalance Current imbalance rate = (maximum phase current - minimum phase current) / maximum phase current × 100%
Current imbalance rate ≥ set current imbalance rate setting range: 10~50%
Adjustable from 1 to 10 seconds
Ground Exceeding the setting ground current value setting range: OFF, 0.03~10A Adjustable from 0.05 to 10 seconds
EOCR-3MZ2/FMZ2 technical parameters
Current range Overcurrent Definite time: 0.5-60A, greater than 60A using external CT
Inverse time limit: 0.5-32A, about 32A using external CT
Undercurrent 0.5A~OC set value
Current-time characteristics Definite time limit, inverse time limit, overheating inverse time limit
time setting Definite time limit D-time 0~200 seconds
O-time 0.2~30 seconds
Inverse time/overheating inverse time limit 1~30 level
Ground delay time 0~30 seconds
Grounding action time 0.05~10 seconds
Automatic reset 0.5 seconds to 20 minutes
Reset form Manual, electric, automatic
Operating power supply Voltage 85~260VAC/DC (85%~110%), 24VAC/DC (±5%)
frequency 50/60HZ
Power consumption Less than 7VA
display Seven-segment digital display Three-phase current value and leakage current cycle display, fault cause, setting parameters
Current amplitude display stick The actual running current amplitude is displayed on the spot (65%~100%)
communication Modbus/RS-485
Installation method switchboard
Embedded panel
surroundings temperature Storage -40°C~+85°C
run -20°C~+60°C
humidity No condensation state 30-85% RH
insulation insulation Between the outer casing and the line Greater than DC500V 10 megohms
Compressive strength Between the outer casing and the line 2KV 50/60Hz 1 minute
Output contact 1KV 50/60Hz 1 minute
Line room 2KV 50/60Hz 1 minute

Http://news.chinawj.com.cn Schneider Korea Sanhe EOCR-FMZ2-WRCUW motor protector Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn Schneider Korea Sanhe EOCR-FMZ2-WRCUW motor protector

Wooden Sleeper

Railroad construction wooden sleeper characteristics
Wooden sleepers ,also called Pinus Sylvestris Wooden Tie,Rail Wood Ties,Rail Hardwood Sleepers,Rail Hardwood Ties, has good elasticity, light weight, easy fabrication, and other significant characteristics of insulation performance is good. Fasteners with wood blocking connection simple, laying and maintenance, transportation is convenient, wooden sleeper and have bigger friction coefficient between gravel ballast. Wooden sleeper toughening corrosion, can absorb more than other sleeper train weight and less prone to fracture. But its drawback is that use fixed number of year is shorter, consumption of large amount of wood. Wooden sleeper easy to corrupt, the reason from insect pests, the influence of the environment and climate, and the spike on the wood blocking hole by using long relaxation, wooden sleeper most commonly so only decades of life. To effectively extend the service life, sleepers generally must be used after filling the anti-corrosion. The sleepers, now use are embalmed, to prevent pests and to extend the use fixed number of year.

Pinus Sylvestris Wooden Tie,Rail Wood Ties,Rail Hardwood Sleepers,Rail Hardwood Ties

TAICANG ZHONGBO RAILWAY FASTENING CO., LTD. , https://www.railfastener.com